| * Copyright (c) 2018 Contributors to the Eclipse Foundation |
| * |
| * See the NOTICE file(s) distributed with this work for additional |
| * information regarding copyright ownership. |
| * |
| * This program and the accompanying materials are made available under the |
| * terms of the Eclipse Public License v. 2.0 which is available at |
| * http://www.eclipse.org/legal/epl-2.0. |
| * |
| * SPDX-License-Identifier: EPL-2.0 |
| ******************************************************************************* |
| */ |
| |
| export const RESSOURCEWITHTYPERESPONSEEMPTYLIST = ` |
| <ResponseMessage> |
| <Header> |
| <Verb>reply</Verb> |
| <Noun>PowerSystemResources</Noun> |
| <Revision>1</Revision> |
| <Timestamp>2018-07-09T07:35:02.144Z</Timestamp> |
| <Source>DynamicTopologyService</Source> |
| <User> |
| <UserID></UserID> |
| </User> |
| <MessageID>3e3d3b6f-e765-4398-aa03-68a4dcc0fffb</MessageID> |
| </Header> |
| <Reply> |
| <Result>OK</Result> |
| </Reply> |
| <Payload> |
| <PowerSystemResources> |
| </PowerSystemResources> |
| </Payload> |
| </ResponseMessage> |
| `; |
| |
| export const RESSOURCEWITHTYPERESPONSE = ` |
| <ResponseMessage> |
| <Header> |
| <Verb>reply</Verb> |
| <Noun>PowerSystemResources</Noun> |
| <Revision>1</Revision> |
| <Timestamp>2018-07-09T07:35:02.144Z</Timestamp> |
| <Source>DynamicTopologyService</Source> |
| <User> |
| <UserID></UserID> |
| </User> |
| <MessageID>3e3d3b6f-e765-4398-aa03-68a4dcc0fffb</MessageID> |
| </Header> |
| <Reply> |
| <Result>OK</Result> |
| </Reply> |
| <Payload> |
| <PowerSystemResources> |
| <PowerTransformer> |
| <description>PowerTransformer (abddaf44-13e6-46a3-8f87-0d675ea78659)</description> |
| <mRID>abddaf44-13e6-46a3-8f87-0d675ea78659</mRID> |
| <name>PowerTransformer</name> |
| <Terminals> |
| <Terminal> |
| <mRID>22648ddb-9ef9-471c-86e9-9e653354b6b9</mRID> |
| <name>Terminal 1</name> |
| <ConnectivityNode> |
| <ConnectivityNode> |
| <mRID>547146dd-d4aa-48d0-bf1c-d41b3048a372</mRID> |
| </ConnectivityNode> |
| </ConnectivityNode> |
| </Terminal> |
| <Terminal> |
| <mRID>cae79c4c-b877-4382-becb-1438595dbe1a</mRID> |
| <name>Terminal 2</name> |
| <ConnectivityNode> |
| <ConnectivityNode> |
| <mRID>d461607f-f4bb-407a-9be8-1575eefacfb6</mRID> |
| </ConnectivityNode> |
| </ConnectivityNode> |
| </Terminal> |
| </Terminals> |
| <vectorGroup>Dyn1</vectorGroup> |
| <PowerTransformerEnd> |
| <PowerTransformerEnd> |
| <BaseVoltage> |
| <BaseVoltage> |
| <mRID>ea4cf040-cb88-4978-a3a4-630a8f144e4b</mRID> |
| </BaseVoltage> |
| </BaseVoltage> |
| <Terminal> |
| <Terminal> |
| <mRID>22648ddb-9ef9-471c-86e9-9e653354b6b9</mRID> |
| </Terminal> |
| </Terminal> |
| <ratedS> |
| <multiplier>none</multiplier> |
| <unit>VA</unit> |
| <value>20000.0</value> |
| </ratedS> |
| <ratedU> |
| <multiplier>none</multiplier> |
| <unit>V</unit> |
| <value>10000.0</value> |
| </ratedU> |
| </PowerTransformerEnd> |
| <PowerTransformerEnd> |
| <RatioTapChanger> |
| <RatioTapChanger> |
| <highStep>40</highStep> |
| <lowStep>5</lowStep> |
| <normalStep>5</normalStep> |
| <step>20.0</step> |
| <stepVoltageIncrement> |
| <multiplier>none</multiplier> |
| <unit>none</unit> |
| <value>30.0</value> |
| </stepVoltageIncrement> |
| </RatioTapChanger> |
| </RatioTapChanger> |
| <BaseVoltage> |
| <BaseVoltage> |
| <mRID>9542f9ef-9a5f-47de-aff5-33f04f362668</mRID> |
| </BaseVoltage> |
| </BaseVoltage> |
| <Terminal> |
| <Terminal> |
| <mRID>cae79c4c-b877-4382-becb-1438595dbe1a</mRID> |
| </Terminal> |
| </Terminal> |
| <ratedS> |
| <multiplier>none</multiplier> |
| <unit>VA</unit> |
| <value>20000.0</value> |
| </ratedS> |
| <ratedU> |
| <multiplier>none</multiplier> |
| <unit>V</unit> |
| <value>400.0</value> |
| </ratedU> |
| </PowerTransformerEnd> |
| </PowerTransformerEnd> |
| </PowerTransformer> |
| </PowerSystemResources> |
| </Payload> |
| </ResponseMessage> |
| `; |
| |
| export const RESSOURCEWITHTYPERESPONSE_2 = ` |
| <ResponseMessage> |
| <Header> |
| <Verb>reply</Verb> |
| <Noun>PowerSystemResources</Noun> |
| <Revision>1</Revision> |
| <Timestamp>2018-07-09T09:15:56.986Z</Timestamp> |
| <Source>DynamicTopologyService</Source> |
| <User> |
| <UserID></UserID> |
| </User> |
| <MessageID>d0383f7e-e89f-4291-847c-6a5007aac5ae</MessageID> |
| </Header> |
| <Reply> |
| <Result>OK</Result> |
| </Reply> |
| <Payload> |
| <PowerSystemResources> |
| <ACLineSegment> |
| <mRID>ebb8f129-3e4f-4200-bb96-ba384c911c83</mRID> |
| <name>South ACLineSegment</name> |
| <BaseVoltage> |
| <BaseVoltage> |
| <mRID>9542f9ef-9a5f-47de-aff5-33f04f362668</mRID> |
| </BaseVoltage> |
| </BaseVoltage> |
| <Terminals> |
| <Terminal> |
| <mRID>ae19e738-59ce-466d-840d-cafb06b4ad16</mRID> |
| <name>Terminal 1</name> |
| <ConnectivityNode> |
| <ConnectivityNode> |
| <mRID>49079d8e-9478-4560-a958-9dae258254e2</mRID> |
| </ConnectivityNode> |
| </ConnectivityNode> |
| </Terminal> |
| <Terminal> |
| <mRID>78b3a4ad-154d-4ace-9fa9-d881b38debb2</mRID> |
| <name>Terminal 2</name> |
| <ConnectivityNode> |
| <ConnectivityNode> |
| <mRID>ed79abaf-10f9-4bc7-93d9-64ab205fcf5d</mRID> |
| </ConnectivityNode> |
| </ConnectivityNode> |
| </Terminal> |
| </Terminals> |
| <length> |
| <multiplier>none</multiplier> |
| <unit>m</unit> |
| <value>500000.0</value> |
| </length> |
| <PerLengthImpedance> |
| <PerLengthSequenceImpedance> |
| <WireInfos> |
| <WireInfo> |
| <ratedCurrent> |
| <multiplier>none</multiplier> |
| <unit>A</unit> |
| <value>2.0</value> |
| </ratedCurrent> |
| </WireInfo> |
| </WireInfos> |
| <r> |
| <multiplier>none</multiplier> |
| <unit>ohm</unit> |
| <value>0.5</value> |
| </r> |
| <x> |
| <multiplier>none</multiplier> |
| <unit>ohm</unit> |
| <value>0.3</value> |
| </x> |
| </PerLengthSequenceImpedance> |
| </PerLengthImpedance> |
| </ACLineSegment> |
| <ACLineSegment> |
| <mRID>1efdad09-d26f-4f1b-be82-7f63ef474c42</mRID> |
| <name>North ACLineSegment</name> |
| <BaseVoltage> |
| <BaseVoltage> |
| <mRID>9542f9ef-9a5f-47de-aff5-33f04f362668</mRID> |
| </BaseVoltage> |
| </BaseVoltage> |
| <Terminals> |
| <Terminal> |
| <mRID>d4b3980f-8cf5-4840-aed3-e23c5dd2689a</mRID> |
| <name>Terminal 1</name> |
| <ConnectivityNode> |
| <ConnectivityNode> |
| <mRID>23fe5dd0-7969-4d23-9b91-05db9598186e</mRID> |
| </ConnectivityNode> |
| </ConnectivityNode> |
| </Terminal> |
| <Terminal> |
| <mRID>ed4cbd93-fefb-48c9-abf4-e94e2f3b8ac4</mRID> |
| <name>Terminal 2</name> |
| <ConnectivityNode> |
| <ConnectivityNode> |
| <mRID>49079d8e-9478-4560-a958-9dae258254e2</mRID> |
| </ConnectivityNode> |
| </ConnectivityNode> |
| </Terminal> |
| </Terminals> |
| <length> |
| <multiplier>none</multiplier> |
| <unit>m</unit> |
| <value>500000.0</value> |
| </length> |
| <PerLengthImpedance> |
| <PerLengthSequenceImpedance> |
| <WireInfos> |
| <WireInfo> |
| <ratedCurrent> |
| <multiplier>none</multiplier> |
| <unit>A</unit> |
| <value>2.0</value> |
| </ratedCurrent> |
| </WireInfo> |
| </WireInfos> |
| <r> |
| <multiplier>none</multiplier> |
| <unit>ohm</unit> |
| <value>0.5</value> |
| </r> |
| <x> |
| <multiplier>none</multiplier> |
| <unit>ohm</unit> |
| <value>0.3</value> |
| </x> |
| </PerLengthSequenceImpedance> |
| </PerLengthImpedance> |
| </ACLineSegment> |
| </PowerSystemResources> |
| </Payload> |
| </ResponseMessage> |
| `; |
| |
| export const RESSOURCETYPESRESPONSE = ` |
| <ResponseMessage> |
| <Header> |
| <Verb>reply</Verb> |
| <Noun>PowerSystemResourceTypes</Noun> |
| <Revision>1</Revision> |
| <Timestamp>2018-07-09T07:54:24.275Z</Timestamp> |
| <Source>DynamicTopologyService</Source> |
| <User> |
| <UserID></UserID> |
| </User> |
| <MessageID>c99f30dd-62a9-4461-91fa-9d654fd6ef91</MessageID> |
| </Header> |
| <Reply> |
| <Result>OK</Result> |
| </Reply> |
| <Payload> |
| <PowerSystemResourceTypes> |
| <PSRType> |
| <name>ac-line-segment</name> |
| </PSRType> |
| <PSRType> |
| <name>base-voltage</name> |
| </PSRType> |
| <PSRType> |
| <name>bay</name> |
| </PSRType> |
| <PSRType> |
| <name>breaker</name> |
| </PSRType> |
| <PSRType> |
| <name>busbar-section</name> |
| </PSRType> |
| <PSRType> |
| <name>disconnector</name> |
| </PSRType> |
| <PSRType> |
| <name>earth-fault-compensator</name> |
| </PSRType> |
| <PSRType> |
| <name>energy-consumer</name> |
| </PSRType> |
| <PSRType> |
| <name>energy-source</name> |
| </PSRType> |
| <PSRType> |
| <name>geographical-region</name> |
| </PSRType> |
| <PSRType> |
| <name>ground</name> |
| </PSRType> |
| <PSRType> |
| <name>grounding-impedance</name> |
| </PSRType> |
| <PSRType> |
| <name>junction</name> |
| </PSRType> |
| <PSRType> |
| <name>line-type</name> |
| </PSRType> |
| <PSRType> |
| <name>load-break-switch</name> |
| </PSRType> |
| <PSRType> |
| <name>petersen-coil</name> |
| </PSRType> |
| <PSRType> |
| <name>plant</name> |
| </PSRType> |
| <PSRType> |
| <name>power-transformer</name> |
| </PSRType> |
| <PSRType> |
| <name>sub-geographical-region</name> |
| </PSRType> |
| <PSRType> |
| <name>substation-type</name> |
| </PSRType> |
| <PSRType> |
| <name>voltage-level</name> |
| </PSRType> |
| </PowerSystemResourceTypes> |
| </Payload> |
| </ResponseMessage> |
| `; |